Bosch Climate 5000 units report faults with a letter and a digit on the indoor display. The codes differ by indoor unit type, so check which type you have first. This guide uses the official Bosch service manual tables.
Which table applies to your unit
Bosch lists three indoor unit types: wall mounted, four-way cassette, and ducted. The same code can mean different things on different types, so match your unit type to the table before reading the code.
Wall mounted indoor unit
| Code | Meaning |
|---|---|
| E0 | Indoor unit EEPROM error |
| E1 | Communication error between indoor and outdoor units |
| E3 | Indoor fan speed error |
| E4 | Indoor return air temperature sensor error |
| E5 | Indoor coil temperature sensor error |
| EC | Low refrigerant |
| F0 | Outdoor current overload |
| F1 | Outdoor ambient temperature sensor error |
| F2 | Outdoor coil temperature sensor error |
| F3 | Compressor discharge temperature sensor error |
| F4 | Outdoor unit EEPROM error |
| F5 | Outdoor unit fan speed error |
| F6 | Indoor coil outlet temperature sensor error |
| P0 | Inverter module (IPM) error |
| P1 | High or low voltage protection |
| P3 | Outdoor unit low temperature lockout |
| P4 | Compressor drive error |
| P5 | Mode conflict |
Four-way cassette indoor unit
| Code | Meaning |
|---|---|
| E0 | Indoor EEPROM error |
| E1 | Indoor and outdoor unit communication malfunction |
| E3 | Indoor fan speed malfunction |
| E4 | Indoor room temperature sensor error |
| E5 | Evaporator coil temperature sensor error |
| EC | Refrigerant leak detection system malfunction |
| EE | Water level alarm malfunction |
| E8 | Dual indoor unit (twin) communication malfunction |
| E9 | Other twin model malfunction |
| F0 | Overload protection |
| F1 | Outdoor temperature sensor error |
| F2 | Outdoor condenser pipe sensor error |
| F3 | Discharge air temperature sensor error |
| F4 | Outdoor EEPROM error |
| F5 | Outdoor fan speed (DC fan motor) malfunction |
| F7 | Auto-lifting panel communication error |
| F8 | Auto-lifting panel malfunction |
| F9 | Auto-lifting panel is open |
| P0 | Inverter module IPM protection |
| P1 | High/low voltage protection |
| P2 | Compressor top overheating protection |
| P3 | Outdoor low temperature protection |
| P4 | Compressor drive error |
| P5 | Mode conflict |
| P6 | Compressor low-pressure protection |
| P7 | Outdoor IGBT sensor error |
Ducted indoor unit
| Code | Meaning |
|---|---|
| E0 | Indoor EEPROM error |
| E1 | Indoor and outdoor unit communication malfunction |
| E3 | Indoor fan speed malfunction |
| E4 | Indoor room temperature sensor error |
| E5 | Evaporator coil temperature sensor error |
| EC | Refrigerant leak detection system malfunction |
| EE | Water level alarm malfunction |
| E8 | Dual indoor unit (twin) communication malfunction |
| E9 | Other twin model malfunction |
| F0 | Overload protection |
| F1 | Outdoor temperature sensor error |
| F2 | Outdoor condenser pipe sensor error |
| F3 | Discharge air temperature sensor error |
| F4 | Outdoor EEPROM error |
| F5 | Outdoor fan speed (DC fan motor) malfunction |
| P0 | Inverter module IPM protection |
| P1 | High/low voltage protection |
| P2 | Compressor top overheating protection |
| P3 | Outdoor low temperature protection |
| P4 | Compressor drive error |
| P5 | Mode conflict |
| P6 | Compressor low-pressure protection |
| P7 | Outdoor IGBT sensor error |
| FA | Indoor unit communication malfunction |
What to do when you see a code
- Turn the unit off and note the code, the unit type and whether the code is on the indoor display or the remote.
- Clean the air filter and check that the indoor and outdoor units have clear airflow. Do this only with the unit off.
- Wait about 30 seconds, turn the unit back on, and check whether the code returns.
- If the code returns, or it is a P code, an F code, an E3 or EC, call a licensed Bosch technician. Do not open the outdoor unit or handle refrigerant or electrical parts yourself.